# Multi-Family Insulation: The Practical K-13 Guide

- [Ross Bahl](https://bahlfireproofing.com/author/rossbahl/)
- October 13, 2026
- 10:00 am

Multi-family insulation: the practical k-13 guide 2

Multi-family developers and property managers call about sprayed insulation for one reason, and that reason is almost always noise. The trouble is that two completely different sound problems share the same word. This article separates them, explains what the building code requires between apartments, and shows where multi-family insulation earns its place in an apartment community and where it does not.

**TLDR:** Multi-family insulation gets bought for the wrong sound problem. Noise reduction coefficient measures absorption inside a room, while sound transmission class and impact insulation class measure transmission between rooms and are properties of a tested assembly, so no sprayed coating makes a floor and ceiling assembly comply between apartments. K-13 earns its keep one level down, and the placement rule is the part worth reading.

---

## The Noise Complaint a Sprayed Ceiling Will Not Fix

The costly version of this mistake is not a rejected submittal. It is a change order signed after the building is occupied, on a scope that was never going to work, and the shape repeats. A property manager collects a stack of noise complaints during lease-up. Footsteps overhead, a chair scraping at midnight, a television through the party wall. Someone proposes spraying the underside of the floor deck, because sprayed multi-family insulation is the acoustic product everybody has heard of. The spray goes in, the complaints keep coming, and the residents who complained loudest do not renew.

Now the real fix is on the table, and it is structural: a topping slab, a resilient underlayment, a decoupled ceiling, or sealing a flanking path through a common chase. All of those are demolition inside occupied apartments. Getting the measurement wrong at design costs a coating. Getting it wrong after certificate of occupancy costs a renovation and a year of turnover.

## What the Code Actually Requires Between Apartments

Sound isolation between dwelling units is a code requirement, not a marketing preference. In the 2024 edition of the International Building Code it lives in Section 1206, titled Sound Transmission. Name the edition when you cite it, because it moved: the 2015 edition numbered this material Section 1207, and it has been Section 1206 from the 2018 edition onward.

Section 1206.1 sets the scope, and the scope is where most competing pages go loose. The requirement attaches to common interior walls, partitions, and floor and ceiling assemblies between adjacent dwelling units, between sleeping units, and between dwelling or sleeping units and adjacent public or service areas. It is keyed to dwelling units and sleeping units, not to Group R-2 as an occupancy label. A building with apartments over ground-floor retail carries it at the boundary between the units and those service areas, whatever letter sits on the rest of the plan.

Section 1206.2 covers airborne sound. It requires a sound transmission class of not less than 50 when tested in a laboratory to [ASTM E90 laboratory measurement of airborne sound transmission loss](https://store.astm.org/e0090-23.html), with a field alternative of a normalized noise isolation class of not less than 45 tested to ASTM E336. Entrance doors to dwelling units carry a lower figure, a sound transmission class of not less than 28.

Section 1206.3 covers structure-borne sound, which is the footfall complaint. It requires an impact insulation class of not less than 50 tested to ASTM E492, with a field alternative of not less than 45 tested to ASTM E1007. The metric name on that field test is edition-dependent and it trips people up: the 2021 edition calls it NISR, the 2024 edition calls it AIIC, and the number and method stay the same. Confirm the adopted edition with the authority having jurisdiction before writing any of this into a submittal.

## The Pattern I See on Multi-Family Insulation Calls

I have been spraying insulation and fire protection across Texas, Kansas, and Oklahoma for more than twenty years, and the apartment calls arrive in two shapes. One is a developer or property manager who has been told sprayed insulation will solve noise complaints between units. The other is a general contractor asking about a podium parking ceiling, and that second call is usually right.

The first one almost never fails for the reason the caller thinks. People assume the building got cheap insulation. What actually happened is that the floor and ceiling assembly was drawn to a number nobody verified, or it was drawn correctly and then built with a penetration, a duct chase, or a partition that stops short of the deck. Sound found the path around the assembly, and no surface material closes a flanking path, because the path is not on the surface.

So we ask three questions before quoting an apartment building. Is the complaint inside one room or between two? If between two, which assembly separates them and what does it test at? Is there a penetration or a chase connecting them? Those answers put the job with the right trade, and about half the time that trade is not us.

## Absorption, Airborne, and Impact Are Three Different Measurements

They use different standards, describe different physics, and only two are code requirements. The table below is the page to hand an owner who has been told that multi-family insulation will fix a party-wall complaint.

Question Noise reduction coefficient Sound transmission class Impact insulation class

What it measures Sound absorbed within a space Airborne sound blocked between spaces Footfall sound blocked between spaces

Test standard ASTM C423 ASTM E90 ASTM E492

Property of A material at a stated thickness and mounting A complete tested assembly A complete tested floor and ceiling assembly

The complaint it answers Echo, reverberation, announcements nobody can make out Voices, television, music through a wall Footsteps, dropped objects, chairs scraping

Where the code requires it No requirement in the building code 2024 International Building Code Section 1206.2 2024 International Building Code Section 1206.3

Laboratory minimum None stated Not less than 50 Not less than 50

Field alternative Not applicable Not less than 45, per ASTM E336 Not less than 45, per ASTM E1007

Published K-13 value Yes, by thickness and substrate None None

What actually delivers it An exposed absorptive ceiling or wall finish Mass, decoupling, cavity depth, sealed penetrations Topping slabs, resilient underlayment, resilient channel, decoupled ceilings

Read the last two rows together and the argument is finished. A sprayed coating has published absorption data and no published transmission data, because transmission is not a property a coating can have. No honest submittal converts one into the other.

## What K-13 Publishes, and What Those Numbers Control

K-13 is a spray-applied thermal and acoustical insulation used as an exposed ceiling finish, applied wet with adhesive over a structural deck. The manufacturer is International Cellulose Corporation of Houston, which abbreviates itself ICC. The International Code Council uses the same three letters, so keep the two apart on a submittal. Only contractors licensed by International Cellulose install it.

The published figures worth carrying into an apartment specification are short. Thermal resistance is R-3.7 per inch, a material property rather than a compliance value. Bond strength exceeds 150 pounds per square foot tested to ASTM E736. Nominal density is 3.5 pounds per cubic foot per UL ER5499-01, revised September 19, 2016. It goes up to 5 inches thick in a single application without mechanical support, and thicker work moves to the K-13 High-R System. Five standard colors are offered, Black, Gray, Light Gray, White, and Tan, plus custom matching.

One boundary matters on a residential project. K-13 is not a fireproofing product and contributes no fire-resistance rating of its own. Rated steel gets a spray-applied fire-resistive material, and K-13 is listed as an allowable sprayed fiber over it. Confirm the design number in UL Product iQ.

Absorption is reported as a noise reduction coefficient measured to [ASTM C423 sound absorption by the reverberation room method](https://store.astm.org/c0423-23e01.html), and it is usable only with both a thickness and a substrate attached.

Assembly under the spray Applied thickness Published noise reduction coefficient

Solid backing 1 inch 0.80

Solid backing 1.5 inches 0.90

Solid backing 1.75 inches 1.00

Solid backing 2 inches 1.00

Solid backing 3 inches 1.00

Solid backing 4 inches 1.05

Solid backing 5 inches 1.00

1.5-inch metal deck 1.5 inches 1.05

1.5-inch metal deck 3 inches 1.05

2-inch metal deck 1 inch 0.90

2-inch metal deck 2 inches 1.05

3-inch metal deck 1 inch 0.95

3-inch metal deck 1.5 inches 1.00

3-inch metal deck 2.75 inches 1.05

Two things fall out, and the second is the number to remember. The curve is not monotonic: on solid backing it peaks at 1.05 at 4 inches and falls back to 1.00 at 5, so thicker is not automatically better. And the substrate outweighs the material. The same 1.5 inches reads 0.90 over solid backing and 1.05 over 1.5-inch metal deck, because the flutes add cavity depth behind the fiber. Matching that 1.05 on solid backing takes 4 inches, another 2.5 inches of material. The deck profile is worth more than an inch and a half of extra spray, which is why multi-family insulation gets priced off the deck section.

## Where Multi-Family Insulation Belongs in an Apartment Community

Not between the units. That is an assembly problem. The places an exposed sprayed finish does honest work share three traits: the structure is already exposed, the surfaces are hard, and the room is shared.

**Parking podium ceilings.** The best fit in the building type. The deck is exposed by design, the walls are concrete, and engine noise, door slams, and alarm chirps have nowhere to go. It is also a floor over unconditioned space with dwelling units above.

**Breezeways and exposed corridors.** Garden-style and wrap communities across our region run open circulation with exposed framing overhead, and those ceilings are visible, so color matters as much as absorption.

**Amenity rooms, fitness rooms, and clubhouses.** A fitness room is a hard-surfaced box with dropped weights and a sound system in it. Absorption there improves the resident experience and lowers the level pressing on the wall assembly.

**Mail, package, and trash rooms.** Small, hard, and used at all hours, and package rooms have gone from a closet to a real room with roll cages in it.

**High-volume lobbies and leasing offices.** A double-height lobby is where prospective residents form an opinion, and a room nobody can hold a conversation in reads as cheap whatever the finishes cost.

We priced a five-story wrap community where the specification called for multi-family insulation on the parking podium at a noise reduction coefficient of 1.05, with no thickness and no mounting named. On solid backing that is a 4-inch application. The podium was 3-inch composite deck, where 2.75 inches reaches the same figure, and much of the soffit was formed concrete rather than deck. One number, three thicknesses depending on which bay you stood under.

## How an Exposed Sprayed Ceiling Gets Approved Over Residents

Two separate code routes apply to multi-family insulation left exposed on an apartment ceiling, and they get collapsed into one.

The first is insulation. Section 807 of the 2024 International Building Code covers insulation and sends it to Section 720, Thermal- and Sound-Insulating Materials. Section 720 splits by installed condition: Section 720.2 for concealed installation and Section 720.3 for exposed installation. An exposed ceiling finish lands in 720.3. They are not an exception pair. Both impose the same limits, a flame spread index of not more than 25 and a smoke developed index of not more than 450, and the exception in 720.2 covers cellulosic loose-fill, which K-13 is not.

The second is interior finish by occupancy, in Table 803.13 in the 2018, 2021, and 2024 editions. The 2015 edition numbered that same table 803.11, and 2015 Section 803.12 is a different subject titled Stability. Section 803.1.2 defines the classes: Class A is a flame spread index of 0 to 25 with a smoke developed index of 0 to 450, Class B runs 26 to 75, and Class C runs 76 to 200.

Keep the threshold and the test result apart. Tested to ASTM E84, K-13 returns a flame spread index of 5 and a smoke developed index of 5. Those are measured results, not a class designation. The [International Code Council](https://www.iccsafe.org/) publishes these provisions, and the adopted edition varies by jurisdiction.

## Multi-Family Insulation in Texas, Kansas, and Oklahoma

Apartments are going up hard across all three states, and a developer reusing one prototype from Austin to Wichita meets a different code edition at each stop.

Start with a clarification that saves an argument. The Section 1206 sound requirements come from the building code, not the energy code, so they do not move when a city changes energy editions. What moves is the building code edition itself, which is why the same requirement reads 1207 on a 2015-edition set and 1206 on a 2024-edition set.

The energy side is where the three states genuinely diverge. Texas is on the 2015 IECC, effective November 1, 2016 under 34 Texas Administrative Code 19.53(a), and its scope reaches commercial and industrial buildings plus residential buildings taller than three stories, meaning Groups R-2, R-3, and R-4, while excluding one- and two-family residences of three stories or fewer. Oklahoma adopted the 2006 IECC along with ASHRAE 90.1-2003, effective September 14, 2022, a 2022 effective date on a 2006 edition. Kansas names the 2006 IECC as its standard for new commercial and industrial structures under K.S.A. 66-1227, but Kansas is a home-rule state, so adoption and enforcement sit locally.

Home-rule cities amend upward, and that is the sharp edge for an apartment developer. Dallas enforces the 2021 IECC while Fort Worth is still on the 2015. Same podium detail, two editions, twenty miles apart. In the 2021 edition, Table C402.1.3 carries a higher continuous-insulation row for Group R mass walls than for all other occupancies, R-7.6ci in Climate Zone 2 against R-5.7ci, so a wall detail that clears on an office can fail on an apartment building. That figure governs only where a jurisdiction amended up to it, as Dallas has.

Climate zone matters to the podium, a floor over unconditioned parking with dwelling units above. Houston is Climate Zone 2A. Dallas-Fort Worth, Oklahoma City, and Tulsa are 3A. Wichita is 4A. The governing number for multi-family insulation comes from the opaque envelope table in the edition your building official enforces, for your climate zone and your assembly, and floors over unconditioned space carry their own row.

## Specifying Multi-Family Insulation on an Apartment Project

1. **Sort the complaint before you sort the product.** Inside one room is absorption. Between two rooms is transmission, and transmission belongs to the assembly.
1. **Pull the Section 1206 numbers from the adopted edition.** Not less than 50 in the laboratory for both metrics, not less than 45 in the field.
1. **Send the party wall and the floor and ceiling assembly to the licensed architect or engineer.** Assembly selection, flanking paths, and penetration detailing are design decisions, not finish decisions.
1. **Draw the sprayed scope only in shared and exposed-structure spaces.** Podium ceilings, breezeways, amenity and fitness rooms, mail and package rooms, trash rooms, and lobbies.
1. **Get the deck profile before naming an absorption number.** Flute depth moves the result more than an extra half inch of material does.
1. **Name a thickness and a substrate on every acoustic line item.** A bare noise reduction coefficient is not a specification.
1. **Approve color under the installed lighting, and keep the fire-resistance scope separate.** Rated steel gets a fire-resistive material, and sprayed fiber goes over it only inside a listed design.

We will not publish a per-square-foot figure for this work and no one else should. No credible published installed price exists for sprayed apartment ceilings in this market. Height, access, deck profile, thickness, color, masking, and occupied-building phasing all move it. Get a project bid.

## Related Reading

- [K-13 Acoustic Performance: NRC Ratings by Thickness](https://bahlfireproofing.com/k-13-acoustic-performance-nrc-ratings/) works through the thickness and substrate combinations in more depth.
- [Fireproofing for Multi-Family and Apartments](https://bahlfireproofing.com/fireproofing-for-multi-family-and-apartments/) covers passive fire protection in residential construction, a separate scope from insulation.
- [Spray Foam Insulation for Parking Structures](https://bahlfireproofing.com/spray-foam-insulation-for-parking-structures/) compares the options for a parking deck ceiling where thermal performance leads.

## Frequently Asked Questions

**Does K-13 stop noise between apartments?** No. It absorbs sound inside the room it is sprayed in, which lowers reverberation there. Sound moving between apartments is transmission, measured as sound transmission class and impact insulation class, and both belong to a complete tested assembly. International Cellulose publishes neither for K-13.

**What sound isolation does the building code require between dwelling units?** Section 1206 of the 2024 International Building Code requires a sound transmission class of not less than 50 tested to ASTM E90, with a field alternative of a normalized noise isolation class of not less than 45 per ASTM E336. For impact sound it requires an impact insulation class of not less than 50 tested to ASTM E492, with a field alternative of not less than 45 per ASTM E1007. Entrance doors require a sound transmission class of not less than 28.

**Does K-13 reduce noise in an apartment parking garage?** Yes, and the podium ceiling is its best fit in the building type. A parking level is concrete on every side with an exposed deck overhead, so engine noise, door slams, and alarm chirps reverberate. Breezeways, amenity rooms, trash rooms, and lobbies are the other strong candidates.

**Does spraying insulation on a floor deck improve the impact rating?** Not on any published basis. Impact insulation class is measured on the whole floor and ceiling assembly, and what moves it is topping slabs, resilient underlayment, resilient channel, and decoupled ceilings. Ask for the tested assembly.

**How thick should K-13 be on a parking podium ceiling?** It depends on the substrate as much as the target. Over 1.5-inch metal deck, 1.5 inches reaches a noise reduction coefficient of 1.05, while the same figure over solid backing takes 4 inches. Thermal thickness is a separate calculation at R-3.7 per inch, capped at 5 inches.

**Can K-13 be color matched to the building?** Five standard colors are offered, Black, Gray, Light Gray, White, and Tan, plus custom matching. On a breezeway or lobby ceiling, approve a field mock-up under the installed lighting and keep one production run per continuous visual field.

**What does multi-family insulation cost per square foot?** There is no credible published installed price for this market, and any figure circulating as an industry number came from a lead-generation site. Height, access, deck profile, thickness, color, and masking all move it. It has to be bid.

## Key Takeaways

**Absorption and transmission are different problems.**

- Noise reduction coefficient, per ASTM C423, describes a surface inside one room.
- Sound transmission class and impact insulation class, per ASTM E90 and ASTM E492, describe a complete assembly, and nothing converts one into the other.

**The code requirement is keyed to units, not to an occupancy letter.**

- Section 1206.1 of the 2024 International Building Code scopes it to dwelling units, sleeping units, and adjacent public or service areas.
- Section 1206.2 sets a sound transmission class of not less than 50 and Section 1206.3 an impact insulation class of not less than 50, and it was Section 1207 in the 2015 edition.

**Substrate moves the acoustics more than thickness does.**

- The same 1.5 inches reads 0.90 over solid backing and 1.05 over 1.5-inch metal deck.
- On solid backing the peak of 1.05 arrives at 4 inches and falls back to 1.00 at 5, so pull the deck section first.

**Multi-family insulation belongs in the shared and exposed-structure spaces.**

- Podium parking ceilings, breezeways, amenity and fitness rooms, mail and package rooms, trash rooms, and lobbies.
- Between dwelling units is an assembly scope owned by the licensed architect or engineer, and K-13 carries no fire-resistance rating.

**The three states do not share an energy code edition.**

- Texas is on the 2015 IECC, Oklahoma on the 2006 IECC with ASHRAE 90.1-2003, Kansas on the 2006 IECC under home rule.
- Dallas enforces the 2021 IECC while Fort Worth holds the 2015, and sound isolation comes from the building code, so it does not move with it.

If you are building or repositioning an apartment community and you want a crew that sorts the absorption question from the transmission question before it quotes, pulls the deck profile before naming a noise reduction coefficient, keeps the tested score separate from the code class on the submittal, and tells you plainly which ceilings a sprayed finish belongs on, that is the multi-family insulation work we do throughout Texas, Kansas, and Oklahoma. Call me at 512-387-2111 or email ross@bahlfireproofing.com to walk a set with us, or [Contact Bahl Fireproofing](https://bahlfireproofing.com/contact/) to get on the schedule. Our [K-13 sprayed fiber insulation](https://bahlfireproofing.com/k13-sprayed-fiber-insulation/) page covers the exposed-ceiling side of this work, and our [Bahl Fireproofing service areas](https://bahlfireproofing.com/service-areas/) page shows the territory we cover.

---

*This article provides general educational information about insulation, acoustics, and interior finish in multi-family buildings, and it is not engineering, legal, or code-compliance advice. It does not replace project-specific direction from a licensed architect or engineer, and sound transmission class and impact insulation class performance depends on the complete tested assembly and correct installation rather than on any surface material. Product specifications including thermal resistance, noise reduction coefficient, bond strength, density, and color availability are revised by manufacturers, so confirm current values against the latest published data sheet before specifying. Code citations reference a specific edition and the adopted edition varies by the authority having jurisdiction, so confirm current requirements with your local building department. Product suitability depends on project-specific conditions, and installation must follow the manufacturer’s written instructions and be performed by a licensed applicator.*

Written for Bahl Fireproofing**Ross Bahl, Owner**

Ross owns Bahl Fireproofing, the commercial fireproofing and insulation subcontractor his family started in 1977. Every code figure on this site is checked against the published source before it goes up. [More about Ross](/ross-bahl/).

[PrevPreviousCore Foam Cost Guide for Commercial Masonry Projects](https://bahlfireproofing.com/core-fill-cost-commercial-masonry/)

On this page

Bidding this scope?**Send us the drawings.**

Spray-applied fireproofing, intumescent coatings, K-13, spray foam and Core Foam, self-performed across six states. We price the assembly on your drawings, not a square-foot guess.

[Request a bid](/contact/)[Call the office512-387-2111](tel:512-387-2111)

### Have a rated assembly to cover?

Send the drawings and the spec section. We come back with the scope in and the scope out stated plainly, so your bid tab compares the same work across every subcontractor on it.

[Call the office512-387-2111](tel:512-387-2111)[Request a bid](/contact/)

## Keep reading

### [Core Foam Cost Guide for Commercial Masonry Projects](https://bahlfireproofing.com/core-fill-cost-commercial-masonry/)

October 9, 2026

Owners and general contractors budgeting masonry insulation want a number per square foot. No credible published figure exists for Core Foam cost

 [Read the guide](https://bahlfireproofing.com/core-fill-cost-commercial-masonry/)

### [Spray Foam Cost in Kansas and Oklahoma: A 2026 Budget Guide](https://bahlfireproofing.com/spray-foam-cost-kansas-oklahoma/)

October 7, 2026

Owners in Wichita, Tulsa, and Oklahoma City ask the same first question about spray foam cost, and it is the wrong one.

 [Read the guide](https://bahlfireproofing.com/spray-foam-cost-kansas-oklahoma/)

### [Sanctuary Acoustics: The Practical K-13 Ceiling Guide](https://bahlfireproofing.com/sanctuary-acoustics-k-13-worship-centers/)

October 1, 2026

A sanctuary has to do two things a room is not built to do at once. It has to carry an unamplified

 [Read the guide](https://bahlfireproofing.com/sanctuary-acoustics-k-13-worship-centers/)

```json
{"@context":"https:\/\/schema.org","@graph":[{"@type":"Service","@id":"https:\/\/bahlfireproofing.com\/multi-family-insulation-k-13-apartments\/#industry","name":" Fireproofing","url":"https:\/\/bahlfireproofing.com\/multi-family-insulation-k-13-apartments\/","serviceType":"Commercial Fireproofing","provider":{"@id":"https:\/\/bahlfireproofing.com\/#organization"},"areaServed":[{"@type":"State","name":"Texas"},{"@type":"State","name":"Oklahoma"},{"@type":"State","name":"Kansas"},{"@type":"State","name":"Arizona"},{"@type":"State","name":"Wisconsin"},{"@type":"State","name":"Minnesota"},{"@type":"State","name":"Nebraska"}],"isRelatedTo":[{"@type":"Service","name":"Intumescent Fireproofing","url":"https:\/\/bahlfireproofing.com\/intumescent-fireproofing\/"},{"@type":"Service","name":"Spray-Applied Fireproofing","url":"https:\/\/bahlfireproofing.com\/fireproofing\/"},{"@type":"Service","name":"Cementitious Fireproofing","url":"https:\/\/bahlfireproofing.com\/cementitious-fireproofing\/"}]},{"@type":"BlogPosting","@id":"https:\/\/bahlfireproofing.com\/multi-family-insulation-k-13-apartments\/#blogposting","headline":"Multi-Family Insulation: The Practical K-13 Guide","description":"Multi-family insulation: NRC is absorption, STC and IIC belong to the assembly. Where K-13 fits in apartment podiums, breezeways, and amenity rooms.","url":"https:\/\/bahlfireproofing.com\/multi-family-insulation-k-13-apartments\/","datePublished":"2026-10-13T10:00:00-05:00","dateModified":"2026-10-13T10:00:00-05:00","image":{"@type":"ImageObject","url":"https:\/\/bahlfireproofing.com\/wp-content\/uploads\/2026\/08\/multi-family-insulation-k-13-apartments-hero.webp"},"author":{"@type":"Person","@id":"https:\/\/bahlfireproofing.com\/ross-bahl\/#person","name":"Ross Bahl","url":"https:\/\/bahlfireproofing.com\/ross-bahl\/","jobTitle":"Owner"},"publisher":{"@type":"Organization","@id":"https:\/\/bahlfireproofing.com\/#organization","name":"Bahl Fireproofing, LLC","url":"https:\/\/bahlfireproofing.com\/","logo":{"@type":"ImageObject","url":"https:\/\/bahlfireproofing.com\/wp-content\/uploads\/2025\/02\/7ae06-be6a6e71-7409-4c8c-bc8b-c64bc18f6b39-removebg-preview.png"}},"mainEntityOfPage":{"@type":"WebPage","@id":"https:\/\/bahlfireproofing.com\/multi-family-insulation-k-13-apartments\/"},"articleSection":"Fireproofing","keywords":"commercial fireproofing, SFRM, intumescent","about":[{"@type":"Thing","name":"Commercial Fireproofing"},{"@type":"Thing","name":"Fire-Resistive Construction"}],"name":"Multi-Family Insulation: The Practical K-13 Guide"},{"@type":["Person","Organization"],"@id":"https:\/\/bahlfireproofing.com\/#person","name":"Bahl Fireproofing","sameAs":["https:\/\/network.procore.com\/p\/bahl-fireproofing-llc-round-rock","https:\/\/subcontractorsaustintexas.com\/company\/bahl-fireproofing-llc\/","https:\/\/www.yelp.com\/biz\/bahl-fireproofing-round-rock","https:\/\/www.buzzfile.com\/business\/Bahl-Fireproofing-LLC-512-387-2111","https:\/\/subcontractorsaustintexas.com\/company\/bahl-fireproofing-llc\/","https:\/\/members.asaonline.com\/directory\/Details\/bahl-fireproofing-llc-2594032","https:\/\/www.osha.gov\/ords\/imis\/establishment.inspection_detail?id=303410971","https:\/\/www.manta.com\/c\/mm70y4c\/bahl-fireproofing-inc","https:\/\/www.nfca-online.org\/index.php?option=com_community&amp;view=profile&amp;userid=2018789809&amp;module=view-all&amp;uuid=f0c1d73b-33e3-4f07-bc9a-acef2520da51&amp;current_page=0&amp;directory_search_id=2006651#\/profile"],"logo":{"@type":"ImageObject","@id":"https:\/\/bahlfireproofing.com\/#logo","url":"https:\/\/bahlfireproofing.com\/wp-content\/uploads\/2025\/02\/7ae06-be6a6e71-7409-4c8c-bc8b-c64bc18f6b39-removebg-preview.png","contentUrl":"https:\/\/bahlfireproofing.com\/wp-content\/uploads\/2025\/02\/7ae06-be6a6e71-7409-4c8c-bc8b-c64bc18f6b39-removebg-preview.png","caption":"Bahl Fireproofing","inLanguage":"en-US","width":"312","height":"59"},"image":{"@type":"ImageObject","@id":"https:\/\/bahlfireproofing.com\/#logo","url":"https:\/\/bahlfireproofing.com\/wp-content\/uploads\/2025\/02\/7ae06-be6a6e71-7409-4c8c-bc8b-c64bc18f6b39-removebg-preview.png","contentUrl":"https:\/\/bahlfireproofing.com\/wp-content\/uploads\/2025\/02\/7ae06-be6a6e71-7409-4c8c-bc8b-c64bc18f6b39-removebg-preview.png","caption":"Bahl Fireproofing","inLanguage":"en-US","width":"312","height":"59"}},{"@type":"WebSite","@id":"https:\/\/bahlfireproofing.com\/#website","url":"https:\/\/bahlfireproofing.com","name":"Bahl Fireproofing","alternateName":"Bahl Fireproofing LLC","publisher":{"@id":"https:\/\/bahlfireproofing.com\/#person"},"inLanguage":"en-US"},{"@type":"ImageObject","@id":"https:\/\/bahlfireproofing.com\/wp-content\/uploads\/2026\/08\/multi-family-insulation-k-13-apartments-hero.webp","url":"https:\/\/bahlfireproofing.com\/wp-content\/uploads\/2026\/08\/multi-family-insulation-k-13-apartments-hero.webp","width":"1250","height":"1250","caption":"Multi-family insulation: gray sprayed fiber insulation coating a concrete parking podium deck and wrapping a square column head","inLanguage":"en-US"},{"@type":"BreadcrumbList","@id":"https:\/\/bahlfireproofing.com\/multi-family-insulation-k-13-apartments\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":"1","item":{"@id":"https:\/\/bahlfireproofing.com","name":"Home"}},{"@type":"ListItem","position":"2","item":{"@id":"https:\/\/bahlfireproofing.com\/blog\/","name":"Blog"}},{"@type":"ListItem","position":"3","item":{"@id":"https:\/\/bahlfireproofing.com\/category\/fireproofing-blog\/","name":"Fireproofing"}},{"@type":"ListItem","position":"4","item":{"@id":"https:\/\/bahlfireproofing.com\/multi-family-insulation-k-13-apartments\/","name":"Multi-Family Insulation: The Practical K-13 Guide"}}]},{"@type":"WebPage","@id":"https:\/\/bahlfireproofing.com\/multi-family-insulation-k-13-apartments\/#webpage","url":"https:\/\/bahlfireproofing.com\/multi-family-insulation-k-13-apartments\/","name":"Multi-Family Insulation: The Practical K-13 Guide","datePublished":"2026-10-13T10:00:00-05:00","dateModified":"2026-10-13T10:00:00-05:00","isPartOf":{"@id":"https:\/\/bahlfireproofing.com\/#website"},"primaryImageOfPage":{"@id":"https:\/\/bahlfireproofing.com\/wp-content\/uploads\/2026\/08\/multi-family-insulation-k-13-apartments-hero.webp"},"inLanguage":"en-US","breadcrumb":{"@id":"https:\/\/bahlfireproofing.com\/multi-family-insulation-k-13-apartments\/#breadcrumb"}}]}
```